Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 19 de 19
Filtrar
1.
J Vasc Surg Venous Lymphat Disord ; 12(1): 101665, 2024 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-37595746

RESUMO

BACKGROUND: Residual pulmonary vascular occlusion (RPVO) affects one half of patients after a pulmonary embolism (PE). The relationship between the risk factors and therapeutic interventions for the development of RPVO and chronic thromboembolic pulmonary hypertension is unknown. METHODS: This retrospective review included PE patients within a 26-month period who had baseline and follow-up imaging studies (ie, computed tomography [CT], ventilation/perfusion scans, transthoracic echocardiography) available. We collected the incidence of RPVO, percentage of pulmonary artery occlusion (%PAO), baseline CT %PAO, most recent CT %PAO, and difference between the baseline and most recent %PAO on CT (Δ%PAO). RESULTS: A total of 354 patients had imaging reports available; 197 with CT and 315 with transthoracic echocardiography. The median follow-up time was 144 days (interquartile range [IQR], 102-186 days). RPVO was present in 38.9% of the 354 patients. The median Δ%PAO was -10.0% (IQR, -32% to -1.2%). Fewer patients with a provoked PE developed RPVO (P ≤ .01), and the initial troponin level was lower in patients who developed RPVO (P = .03). The initial thrombus was larger in the patients who received advanced intervention vs anticoagulation (baseline CT %PAO: median, 61.2%; [IQR, 27.5%-75.0%] vs median, 12.5% [IQR, 2.5%-40.0%]; P ≤ .0001). Catheter-directed thrombolysis (CDT; median Δ%PAO, -47.5%; IQR, -63.7% to -8.7%) and surgical pulmonary embolectomy (SPE; median Δ%PAO, -42.5; IQR, -68.1% to -18.7%) had the largest thrombus reduction compared with anticoagulation (P = .01). Of the 354 patients, 76 developed pulmonary hypertension; however, only 14 received pulmonary hypertension medications and 12 underwent pulmonary thromboendarterectomy. Cancer (odds ratio [OR], 1.7) and planned prolonged anticoagulation (>1 year; OR, 2.20) increased the risk of RPVO. In contrast, the risk was lower for men (OR, 0.61), patients with recent surgery (OR, 0.33), and patients treated with SPE (OR, 0.42). A larger Δ%PAO was found in men (coefficient, -8.94), patients with a lower body mass index (coefficient, -0.66), patients treated with CDT (coefficient, -18.12), and patients treated with SPE (coefficient, -21.69). A lower Δ%PAO was found in African-American patients (coefficient, 7.31). CONCLUSIONS: The use of CDT and SPE showed long-term benefit in thrombus reduction.


Assuntos
Arteriopatias Oclusivas , Hipertensão Pulmonar , Embolia Pulmonar , Trombose , Masculino , Humanos , Hipertensão Pulmonar/diagnóstico por imagem , Hipertensão Pulmonar/terapia , Hipertensão Pulmonar/complicações , Embolia Pulmonar/diagnóstico por imagem , Embolia Pulmonar/terapia , Embolia Pulmonar/complicações , Fatores de Risco , Trombose/tratamento farmacológico , Estudos Retrospectivos , Anticoagulantes/uso terapêutico , Terapia Trombolítica/efeitos adversos , Terapia Trombolítica/métodos , Resultado do Tratamento
2.
Curr Oncol Rep ; 25(11): 1213-1226, 2023 11.
Artigo em Inglês | MEDLINE | ID: mdl-37695398

RESUMO

PURPOSE OF REVIEW: This review will describe the various applications, benefits, risks, and approaches of conventional irreversible electroporation (IRE), as well as highlight the new technological developments of this procedure along with their clinical applications. RECENT FINDINGS: Minimally invasive image-guided percutaneous IRE ablation has emerged as a newer, non-thermal ablation technique for tumors in the solid organs, particularly within the liver, pancreas, kidney, and prostate. IRE allows for ablation near heat-sensitive structures, including major blood vessels and nerves, and is not susceptible to the heat sink effect. However, it is limited by certain requirements, such as the need for precise parallel placement of at least two probes with a maximum inter-probe distance of 2.5 cm to reduce the risk of arching phenomenon, the requirement for general anesthesia with muscle relaxant, and the need for cardiac synchronization. However, new technological advancements in the ablation system and image guidance tools have been introduced to improve the efficiency and efficacy of IRE. IRE is a safe and effective treatment option for solid tumor ablation within the liver, pancreas, kidney, and prostate. Compared with other ablation techniques, IRE has several advantages, such as the absence of heat sink effect and minimal injury to blood vessels and bile ducts while activating the immune system. Novel techniques such as H-FIRE, needle placement systems, and robotics have enhanced the accuracy and performance in placement of IRE probes. IRE can be especially beneficial when combined with chemotherapy, immunomodulation, and immunotherapy.


Assuntos
Técnicas de Ablação , Neoplasias , Masculino , Humanos , Neoplasias/cirurgia , Eletroporação/métodos , Fígado , Técnicas de Ablação/métodos , Resultado do Tratamento
4.
Diagnostics (Basel) ; 12(6)2022 May 24.
Artigo em Inglês | MEDLINE | ID: mdl-35741109

RESUMO

Image-guided percutaneous ablation methods have been further developed during the recent two decades and have transformed the minimally invasive and precision features of treatment options targeting primary and metastatic tumors. They work by percutaneously introducing applicators to precisely destroy a tumor and offer much lower risks than conventional methods. There are usually shorter recovery periods, less bleeding, and more preservation of organ parenchyma, expanding the treatment options of patients with cancer who may not be eligible for resection. Image-guided ablation techniques are currently utilized for the treatment of primary and metastatic tumors in various organs including the liver, pancreas, kidneys, thyroid and parathyroid, prostate, lung, bone, and soft tissue. This article provides a brief review of the various imaging modalities and available ablation techniques and discusses their applications and associated complications in various organs.

5.
Semin Intervent Radiol ; 38(3): 291-299, 2021 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-34393339

RESUMO

Benign biliary strictures are often due to a variety of etiologies, most of which are iatrogenic. Clinical presentation can vary from asymptomatic disease with elevated liver enzymes to obstructive jaundice and recurrent cholangitis. Diagnostic imaging methods, such as ultrasound, multidetector computed tomography, and magnetic resonance imaging (cholangiopancreatography), are used to identify stricture location, extent, and possible source of biliary obstruction. The management of benign biliary strictures requires a multidisciplinary team approach and include endoscopic, percutaneous, and surgical interventions. Percutaneous biliary interventions provide an alternative diagnostic and therapeutic approach, especially in patients who are not amenable to endoscopic evaluation. This review provides an overview of benign biliary strictures and percutaneous management by interventional radiologists. Diagnostic evaluation with percutaneous transhepatic cholangiography and treatment options, including biliary drainage, balloon dilation, retrievable/biodegradable stents, and other innovative minimally invasive options, are discussed.

6.
Am J Infect Control ; 48(1): 95-99, 2020 01.
Artigo em Inglês | MEDLINE | ID: mdl-31439370

RESUMO

BACKGROUND: To determine if ending the practice of administering prophylactic antibiotics prior to the placement of totally implantable venous access devices (TIVADs) is correlated with an increase in 30-day bloodstream infection-related TIVADs removals. METHODS: The practice of administering prophylactic antibiotics prior to the placement of TIVADs ended in July 2013 at our institution. We compiled a list of patients who had TIVADs placed between July 2010 and July 2016 and cross-referenced this list to a list of patients who had TIVADs removed between July 2010 and August 2016 to evaluate the 30-day bloodstream infection-related TIVAD removals. Retrospective chart review of all patients was performed to collect demographic information, indication for placement, and type of antibiotic administered, if applicable. RESULTS: Over the study period of 6 years, a total of 1,513 TIVADs were placed, of which 28 cases were excluded because of death within 30 days unrelated to TIVAD placement. Of the remaining 1,485 cases, 733 TIVADs were placed in 709 unique patients with prophylactic antibiotic treatment and 752 TIVADs were placed in 709 unique patients without treatment. A total of 8 patients were identified to have TIVADs removed within 30 days owing to infection, of which 4 patients were treated with prophylactic antibiotics. The odds of infection-related removals without prophylactic treatment compared with prophylactic treatment was 0.97 (95% confidence interval, 0.24-3.91; P = .97). CONCLUSIONS: Ending the practice of administrating systemic antibiotic prophylaxis prior to the placement of TIVADs had no effect on the 30-day bloodstream infection-related TIVAD removals rate at our institution. We do not recommend the use of prophylactic antibiotics for the placement of TIVAD.


Assuntos
Antibioticoprofilaxia/estatística & dados numéricos , Bacteriemia/prevenção & controle , Infecções Relacionadas a Cateter/prevenção & controle , Cateterismo Venoso Central/efeitos adversos , Cateteres Venosos Centrais/efeitos adversos , Remoção de Dispositivo/efeitos adversos , Adulto , Idoso , Bacteriemia/epidemiologia , Bacteriemia/microbiologia , Infecções Relacionadas a Cateter/epidemiologia , Infecções Relacionadas a Cateter/microbiologia , Cateteres Venosos Centrais/microbiologia , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Estudos Retrospectivos , Fatores de Risco , Resultado do Tratamento
7.
Radiol Case Rep ; 13(6): 1203-1206, 2018 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-30233760

RESUMO

INTRODUCTION: Transjugular liver biopsy (TJLB) is a minimally invasive procedure performed to obtain hepatic tissue in patients whom standard percutaneous liver biopsy is contraindicated due to abnormal coagulation profile and/or severe ascites. Additionally, it has the advantage of simultaneously measuring the hepatic venous pressures. CASE PRESENTATION: 61-year-old male with history of pulmonary fibrosis, cholecystectomy and Hepatitis C underwent transjugular liver biopsy (TJLB) as part of his lung transplant workup. Shortly after the procedure, the patient developed sharp right upper abdominal pain. Immediate CT of the abdomen and pelvis showed small foci of contrast and gas in the gallbladder fossa and porta hepatis indicating hepatic capsular penetration without perihepatic hematoma or other evidence of hemorrhage. Follow up CT of the abdomen and HIDA scan confirmed the presence of bile leak. Sphincterotomy and stent placement through ERCP was performed. CONCLUSION: Bile leak after a TJLB is a rare, however, potential complication. ERCP and biliary stent seems an effective treatment for persistent symptomatic bile leak post TJLB.

8.
Nucl Med Commun ; 39(10): 915-920, 2018 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-30124600

RESUMO

PURPOSE: Yttrium-90 (Y)-resin microspheres are prescribed using activity. We evaluated overall survival (OS) and radiographic tumor response after selective internal radiation therapy (SIRT) with resin microspheres in patients with liver metastases from colorectal cancer. PATIENTS AND METHODS: We retrospectively reviewed 60 metastatic colorectal cancer patients treated at our institution with SIRT using Y-resin microspheres. Each patient underwent pre-SIRT MRI or computed tomography imaging of the liver with intravenous contrast. Patients underwent post-treatment imaging at 2-3-month intervals with response assessed according to unidimensional Response Evaluation Criteria in Solid Tumors (RECIST) criteria as well as published three-dimensional volumetric criteria. We then related the prescribed activity established by the body surface area method and the corresponding prescribed dose to radiographic treatment response and OS. RESULTS: The median follow-up after the first SIRT treatment was 8.9 months. The mean prescribed activity and the prescribed dose were 26.6 mCi and 52.8 Gy, respectively. OS was not significantly associated with either prescribed activity or prescribed dose. Prescribed dose was also not related to response. However, a significant relationship was found between a higher prescribed activity and an improved radiographic response by RECIST (P=0.04) at the second follow-up. CONCLUSION: The prescribed activity of Y-resin microspheres may be correlated with radiographic response by RECIST criteria at 4-6 months post-treatment. For a more accurate prediction of response, a valid dose calculation model based on post-Y PET dosimetry is likely needed given the heterogeneous dose delivery seen in SIRT.


Assuntos
Resinas Acrílicas/química , Neoplasias Colorretais/patologia , Neoplasias Colorretais/radioterapia , Microesferas , Doses de Radiação , Radioisótopos de Ítrio/química , Radioisótopos de Ítrio/uso terapêutico , Adulto , Idoso , Idoso de 80 Anos ou mais , Braquiterapia , Feminino , Humanos , Neoplasias Hepáticas/secundário , Masculino , Pessoa de Meia-Idade , Dosagem Radioterapêutica , Estudos Retrospectivos , Resultado do Tratamento
9.
Cardiovasc Intervent Radiol ; 40(4): 553-559, 2017 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-28004169

RESUMO

PURPOSE: To compare incidence of port inversion among different types of implantable venous access devices. MATERIALS AND METHODS: Records of patients who underwent imaging-guided subcutaneous port placement without port fixation between July 2001 and April 2015 were reviewed with use of a quality assurance database. 1930 patients with complete follow-up (death or explant) were included in the study. Collected data included date and indication for port placement, port type, venous access site, immediate and long-term complications, indication for removal, and total number of catheter days. BMI of patients with inverted ports was also calculated. RESULTS: Port inversion within the pocket was observed in 18 patients (0.9%) including 7/82 (9%) of Dignity ports, 4/126 (3%) of Vaxcel plastic arm ports, 3/142 (2%) of Smartports, 2/100 (2%) of Powerports, 1/14 (7%) of Vaccess ports, and 1/1421 (0.07%) of Vortex LP ports. Among these designs, the inversion rate was significantly lower in Vortex LP ports (0.1%) (P < 0.05). There was a trend toward higher inversion rate of Dignity ports, which have a rectangular design with a relatively narrow base. Mean dwell in inverted ports was 114 days (7-580). CONCLUSION: The incidence of port inversion without suture fixation of the port base to the pocket is extremely low. The present study shows differences in inversion incidence based on port design. LEVEL OF EVIDENCE: Case Series, Level IV.


Assuntos
Cateterismo Venoso Central/instrumentação , Cateteres de Demora/estatística & dados numéricos , Desenho de Equipamento , Falha de Equipamento/estatística & dados numéricos , Cateterismo Venoso Central/estatística & dados numéricos , Bases de Dados Factuais , Seguimentos , Humanos , Incidência , Estudos Prospectivos , Estudos Retrospectivos
10.
J Neuroimaging ; 23(2): 170-4, 2013 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-22211776

RESUMO

PURPOSE: To assess the safety and efficacy of vertebral artery origin angioplasty and stenting for stroke prevention in a multicenter clinical experience. METHODS: Patients with symptomatic vertebral artery origin stenosis (VAOS) were gathered from the Society of Vascular and Interventional Neurology Research Consortium. Demographic, clinical, and procedural data were collected. The main outcome measure was procedural and peri-procedural risks of stroke, transient ischemic attack (TIA), or death at 1 and 3 months. Logistic regression analysis was used to assess covariates associated with future restenosis. RESULTS: A total of 148 patients were included with mean age of 66.2 ± 11.5; 74% men and 77% Caucasian. One patient (.8%) had a stroke at 1 month and 5 of 96 (5.2%) patients had TIA at 3 months. There were no immediate procedural events or deaths. The mean angiographic pre-treatment stenosis was 80.5 ± 12.7%, which was reduced to 5.3 ± 9.1% after stent deployment. Follow-up angiography showed 15.5% of patients had significant restenosis (≥50%). Predictors of restenosis included age (OR 3.08; 95% CI 1.01, 9.41) and smoking (OR 3.10; 95% CI 1.12, 8.64). CONCLUSIONS: Endovascular intervention of VAOS is associated with low peri-procedural complication rates. Restenosis remains a concern; age and smoking predicted future restenosis.


Assuntos
Prótese Vascular/estatística & dados numéricos , Ataque Isquêmico Transitório/mortalidade , Complicações Pós-Operatórias/mortalidade , Stents/estatística & dados numéricos , Acidente Vascular Cerebral/mortalidade , Insuficiência Vertebrobasilar/cirurgia , Idoso , Angiografia Cerebral/estatística & dados numéricos , Comorbidade , Feminino , Humanos , Ataque Isquêmico Transitório/diagnóstico por imagem , Masculino , Complicações Pós-Operatórias/diagnóstico por imagem , Prevalência , Estudos Retrospectivos , Fatores de Risco , Acidente Vascular Cerebral/diagnóstico por imagem , Análise de Sobrevida , Taxa de Sobrevida , Estados Unidos/epidemiologia , Insuficiência Vertebrobasilar/diagnóstico por imagem
11.
J Vasc Interv Radiol ; 23(4): 468-75, 2012 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-22301335

RESUMO

PURPOSE: To report the experience with thoracic endovascular aortic repair (TEVAR) in a single center over a 15-year period. MATERIALS AND METHODS: All patients undergoing TEVAR during the period 1994-2009 were retrospectively evaluated. RESULTS: The study comprised 133 patients (96 men, age 69.5 years ± 14.7) who underwent 21 emergency and 112 elective TEVAR procedures. Aortic pathologies included 91 aneurysms, 14 pseudoaneurysms, 14 penetrating ulcers with or without pseudoaneurysms or intramural hematomas, 8 type B dissections (3 acute and 5 chronic), and 6 traumatic transections. Technical success was 97.7% with a 30-day mortality of 7.5%. There were 101 patients followed to 1 year, 35 patients followed to 5 years, and 6 patients followed to 10-15 years. The overall estimated survivals at 1 year, 5 years, and 10 years were 81%, 48%, and 36%. The 30-day mortality rates in emergency and elective TEVAR procedures were 23.9% and 4.5% (P = .005). However, among patients who survived > 30 days, there was no significant difference in mortality between groups undergoing emergency and elective TEVAR procedures (P = .9, hazard ratio [HR] 0.94, confidence interval [CI] 0.4-2.2). There was no significant gender survival difference. The 30-day mortality rate in octogenarians (n = 31) was higher than in younger patients (P = .03). Incidences of stroke and paraplegia within 30 days of TEVAR were 6.8% and 2.2%. Endoleaks were found in 39 (29%) patients, and secondary interventions were performed in 6 (4.5%) patients. CONCLUSIONS: The data support the safety and efficacy of TEVAR for aortic pathologies with a low mortality rate. Younger patients have fewer complications after TEVAR. After the acute perioperative period, TEVAR procedures performed emergently are as durable as the procedures performed electively.


Assuntos
Aneurisma da Aorta Torácica/mortalidade , Aneurisma da Aorta Torácica/cirurgia , Procedimentos Endovasculares/mortalidade , Radiografia Intervencionista/mortalidade , Adolescente , Adulto , Idoso , Aneurisma da Aorta Torácica/diagnóstico por imagem , Feminino , Humanos , Estudos Longitudinais , Masculino , Pessoa de Meia-Idade , Prevalência , Medição de Risco , Fatores de Risco , Análise de Sobrevida , Taxa de Sobrevida , Resultado do Tratamento , Estados Unidos/epidemiologia , Adulto Jovem
12.
J Vasc Interv Radiol ; 22(9): 1246-53, 2011 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-21741856

RESUMO

PURPOSE: To analyze early and midterm results of endovascular treatment of visceral aneurysms regarding technical considerations, technical success rate, aneurysm rupture, and end-organ ischemia. MATERIALS AND METHODS: Endovascular treatment of 41 visceral and renal artery aneurysms (VAAs) in 40 consecutive patients (25 women; mean age, 59.4 y ± 16.2) was retrospectively reviewed. The series included 30 true aneurysms and 11 pseudoaneurysms in renal (n = 17), splenic (n = 13), hepatic (n = 4), celiac (n = 4), gastroduodenal (n = 2), and middle colic (n = 1) arteries. Demographic, clinical, procedural, and follow-up data were analyzed. RESULTS: Forty-one aneurysms underwent endovascular treatment. Hypertension (73%) and hyperlipidemia (32%) were the most common associated comorbidities. Nineteen patients presented with symptoms of pain (15%) or rupture (32%) in 10 pseudoaneurysms (91%) and nine true aneurysms (30%; P = .0007). The most commonly used technique (93%) was coil embolization with (15%) or without (78%) other endovascular agents. The rate of technical success (cessation of hemorrhage or blood flow into aneurysm sac) was 98%. There was no periprocedural mortality. Mean hospital stays were 1 and 2 days for asymptomatic and symptomatic patients, respectively. Mean clinical follow-up was 44.5 months; mean imaging follow-up was 11.7 months. The only complication was an intraprocedural thromboembolic event in one case (3%). Follow-up imaging evidence of end-organ partial infarct was detected in six patients (21%), with no clinical evidence of organ insufficiency. CONCLUSIONS: Endovascular treatment of VAAs is a safe and highly successful procedure. Associated side effects such as distal embolization and end-organ infarcts were not found to be clinically significant.


Assuntos
Aneurisma/terapia , Embolização Terapêutica , Procedimentos Endovasculares , Artéria Renal , Vísceras/irrigação sanguínea , Adulto , Idoso , Aneurisma/diagnóstico por imagem , Falso Aneurisma/terapia , Embolização Terapêutica/efeitos adversos , Procedimentos Endovasculares/efeitos adversos , Feminino , Florida , Humanos , Estimativa de Kaplan-Meier , Tempo de Internação , Masculino , Pessoa de Meia-Idade , Radiografia , Artéria Renal/diagnóstico por imagem , Estudos Retrospectivos , Medição de Risco , Fatores de Risco , Fatores de Tempo , Resultado do Tratamento
13.
Ann Vasc Surg ; 25(3): 340-4, 2011 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-21276710

RESUMO

BACKGROUND: Many individuals who are candidates for thoracic endovascular aortic repair (TEVAR) are found to have iliac artery anatomy and/or disease that preclude transfemoral endovascular access and require retroperitoneal surgical approach through more proximal arteries. This relatively more invasive technique could potentially affect the procedural outcomes. This study compares the retroperitoneal with transfemoral access used for TEVAR in a single center. METHOD: In this study, 133 consecutive patients (96 men; mean age ± SD: 69.5 ± 14.7 years) who underwent TEVAR between 1994 and 2009 in a single center were retrospectively evaluated. The type of endovascular access was identified in all the patients. The basic demographics, access method, endograft type, 30-day morbidity and mortality rates, as well as procedure recordings including fluoroscopic and procedure duration, estimated blood loss, and duration of hospitalization were compared between the TEVAR procedures performed using a surgical retroperitoneal approach and those using the standard femoral access. RESULTS: Retroperitoneal access was used in 19 (14.3%; 13 women; mean age ± SD: 71 ± 12.2 years) and direct femoral access in 114 (85.7%; 24 women; mean age ± SD: 69 ± 15.4 years) patients. Two of the retroperitoneal accesses were obtained after failure of femoral approach. Techniques that were used included iliac artery conduit (seven patients), aortic artery conduit (eight patients), aortobifemoral artery graft conduit (one patient), and direct sheath introduction through the distal aorta (two patients) or common iliac artery (one patient). Retroperitoneal approach was used more frequently in women (35%) as compared with men (6%) (p = 0.0001). In all, 79% of the retroperitoneal approaches were associated with use of delivery sheath sizes larger than 24F (p = 0.049). TEVAR technical success was 100% with retroperitoneal and 97.3% with femoral access (p > 0.05). Thirty-day mortality rates were 0% and 8.8% and the rates of access artery injury were 5.3% and 4.4% in retroperitoneal and femoral access groups, respectively (p > 0.05). The incidence of retroperitoneal hematoma was significantly higher with retroperitoneal access (21% vs. 2.6%, p = 0.008). Additionally, retroperitoneal access was associated with significant increase in estimated blood loss and duration of hospitalization (p < 0.05). CONCLUSIONS: Type of access does not affect TEVAR success and the early mortality rate. Retroperitoneal approach is a valuable alternative technique in cases involving failed or impossible femoral access. However, this approach is associated with higher chances of retroperitoneal bleeding and longer procedural time and duration of hospitalization. Thoracic endografts with smaller delivery systems could minimize the need for this approach in the future.


Assuntos
Aorta Torácica/cirurgia , Doenças da Aorta/cirurgia , Implante de Prótese Vascular , Procedimentos Endovasculares , Artéria Femoral , Espaço Retroperitoneal/cirurgia , Idoso , Idoso de 80 Anos ou mais , Doenças da Aorta/mortalidade , Prótese Vascular , Implante de Prótese Vascular/efeitos adversos , Implante de Prótese Vascular/instrumentação , Implante de Prótese Vascular/mortalidade , Estudos de Casos e Controles , Procedimentos Endovasculares/efeitos adversos , Procedimentos Endovasculares/instrumentação , Procedimentos Endovasculares/mortalidade , Feminino , Florida , Humanos , Masculino , Pessoa de Meia-Idade , Desenho de Prótese , Estudos Retrospectivos , Medição de Risco , Fatores de Risco , Stents , Fatores de Tempo , Resultado do Tratamento
14.
J Vasc Interv Radiol ; 22(2): 142-7, 2011 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-21194966

RESUMO

PURPOSE: To compare percutaneous suture-mediated closure (PSMC) with surgical closure in endovascular aortic aneurysm repair and examine the influence of obesity, sheath size, and vessel calcification on the effectiveness of percutaneous closure. MATERIALS AND METHODS: A total of 445 patients (mean age, 75.9 ± 7.6 years) undergoing aortic aneurysm repair from 2003 to 2010 were retrospectively reviewed. A total of 100 PSMC and 557 surgical closures for arteriotomies with sheath sizes between 12 F and 18 F were compared in terms of failure, complications, and operating room time. Additionally, effects of arterial calcification, body mass index, and sheath size on PSMC were evaluated. RESULTS: Eighty-five percent of PSMCs were successful. Failure was attributed to lack of hemostasis in 11 and difficulty in device positioning in four cases. Complication rate after successful PSMC (9.4%) was significantly less than surgery (19.4%) (P = .02).When failed PSMC cases were considered as complication, the complication rate was not different between the two groups (P = .4). Seroma occurred more after surgical closures (11.4% vs 1.2%; P = .001). Pseudoaneurysm occurred more after PSMC (3.5% vs 0.18%; P = .008).Average PSMC procedure time was less than that of surgical closure (P = .0001). PSMC success rate was 89.7% for < 16-F sheaths and 80.4% for ≥ 16-F sheaths (P = .15). PSMC success was not different between obese and nonobese patients (P = .22). PSMC success in calcified and noncalcified arteries was not different (P = .37). CONCLUSIONS: PSMC is an effective arterial closure method. It is faster and associated with less postprocedure morbidity than surgery. Appropriate technique and meticulous vascular exposure affect PSMC success. Obesity, vascular calcification, and sheath size did not change PSMC outcome in this study.


Assuntos
Angioplastia/métodos , Aneurisma Aórtico/epidemiologia , Aneurisma Aórtico/cirurgia , Técnicas de Sutura/estatística & dados numéricos , Idoso , Feminino , Humanos , Masculino , Prevalência , Medição de Risco , Fatores de Risco , Resultado do Tratamento , Estados Unidos
15.
J Vasc Interv Radiol ; 21(6): 817-23, 2010 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-20456975

RESUMO

PURPOSE: To evaluate the use of covered stent-grafts in the endovascular treatment (ET) of popliteal artery aneurysms (PAAs). MATERIALS AND METHODS: A retrospective analysis was conducted over a period of 52 months in 18 consecutive patients (17 men; mean age +/- SD, 70 years +/- 11) undergoing ET of PAAs with the Viabahn endograft in a single center. Patient symptoms, aneurysm characteristics, technical outcomes, complications, and follow-up were assessed. RESULTS: Aneurysm diameters ranged from 12 to 51 mm with a mean of 30 mm (+/-11). Thirteen aneurysms (72.2%) were partially thrombosed and 12 patients (66.6%) had symptoms of lower limb ischemia at presentation (11 chronic and one acute). The technical success rate was 94%. Intraprocedural emboli and endoleak occurred in one and two patients, respectively. Fourteen patients were available for follow-up after successful treatment, with a mean follow-up time of 15 months (range, 7-37 months). All stent-grafts were patent after 1 month, with no mortality or limb loss. The primary patency rate with complete exclusion of the aneurysm at 6 months was 86%. Pre- and postprocedural noninvasive arterial studies were available in 10 patients, demonstrating improvement of the ankle-brachial index from 0.96 +/- 0.41 to 1.17 +/- 0.18, respectively (P = .06). CONCLUSIONS: Endovascular stent-graft repair of PAAs is a feasible treatment option. However, further follow-up studies regarding the durability of results are required.


Assuntos
Aneurisma/diagnóstico por imagem , Aneurisma/cirurgia , Prótese Vascular , Artéria Poplítea/diagnóstico por imagem , Artéria Poplítea/cirurgia , Stents , Idoso , Feminino , Humanos , Masculino , Radiografia , Estudos Retrospectivos , Resultado do Tratamento
17.
J Vasc Interv Radiol ; 21(5): 730-4, 2010 May.
Artigo em Inglês | MEDLINE | ID: mdl-20347334

RESUMO

From January 2005 to July 2008, a retrospective study was conducted at a single institution to investigate technical success of the use of a reentry device (Outback LTD reentry catheter) in aortoiliac and femoropopliteal artery recanalization in 34 patients (18 men; mean age +/- SD, 72 years +/- 11) in whom the conventional guide wires and catheters failed to reenter the true lumen. True lumen reentry was achieved in 87% (n = 23) and 91% (n = 11) of patients with femoropopliteal and aortoiliac occlusions, respectively. The overall technical success rate with the device was 88% (n = 34). The device success rate in Transatlantic Inter-Society Consensus II class D lesions was significantly lower than in lower lesion classes (71.4% vs 100%; P < .05). No procedure-related complications were encountered. In conclusion, the use of the reentry catheter enhances the likelihood of successful subintimal recanalization of chronic occlusions in femoropopliteal and aortoiliac arteries.


Assuntos
Arteriopatias Oclusivas/cirurgia , Cateterismo , Artéria Femoral/cirurgia , Extremidade Inferior/irrigação sanguínea , Extremidade Inferior/cirurgia , Idoso , Desenho de Equipamento , Análise de Falha de Equipamento , Feminino , Humanos , Masculino , Estudos Retrospectivos
18.
J Neurointerv Surg ; 2(2): 135-8, 2010 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-21990593

RESUMO

BACKGROUND AND PURPOSE: Thrombus formation during endovascular embolization of intracranial aneurysms occurs in 2.9%-6% of patients. Use of IIb/IIIA inhibitors such as abciximab or eptifibatide intravenously has been reported in management of this complication. Because the intra-arterial infusion of IIb/IIIA inhibitors may require lower doses to achieve thrombolysis, it may reduce the risk of haemorrhage. Therefore, we retrospectively analyze our database and review the literature. METHODS: This is a retrospective analysis of a prospectively acquired database of patients with ruptured or unruptured aneurysm treated intra-arterially for thrombus formation during endovascular coil embolization between July 2005 and August 2008. Patient demographics, aneurysmal characteristics, procedural, clinical outcome and complications were recorded. RESULTS: From July 2005 to August 2008, out of 184 patients who underwent coil embolization, 19 patients (15 smokers, 14 female, mean age 52) developed intraprocedural thrombus formation and received intra-arterial abciximab treatment. Mean aneurysm size was 6.6 mm±4.9 mm; neck size was 3.8 mm±2.1 mm. Eight (42.1%) aneurysms were ruptured. Most aneurysms (63.1%) were in anterior communicating and middle cerebral arteries. Thrombus was visualized in all cases by angiogram and treated intra-arterially with a mean dose of 10.5 mg±4.2. There were no periprocedural hemorrhagic complications. No deaths or other complications occurred during follow-up. CONCLUSION: Thrombus formation during coil embolization of intracranial aneurysms occurred more in women and smokers. Low doses of intra-arterial abciximab may be effective in the thromboembolic complications occurring during endovascular embolization of intracranial aneurysms.


Assuntos
Aneurisma Roto/terapia , Anticorpos Monoclonais/administração & dosagem , Embolização Terapêutica/efeitos adversos , Fragmentos Fab das Imunoglobulinas/administração & dosagem , Aneurisma Intracraniano/terapia , Trombose/tratamento farmacológico , Abciximab , Adulto , Idoso , Idoso de 80 Anos ou mais , Aneurisma Roto/patologia , Embolização Terapêutica/métodos , Feminino , Seguimentos , Humanos , Infusões Intra-Arteriais , Aneurisma Intracraniano/patologia , Masculino , Pessoa de Meia-Idade , Estudos Prospectivos , Estudos Retrospectivos , Trombose/etiologia , Trombose/patologia , Resultado do Tratamento
19.
Int Orthop ; 33(5): 1311-3, 2009 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-19347337

RESUMO

Health professionals have a legal and ethical obligation to obtain a valid consent before any procedure. The aim of this study was to assess the adequacy of consent for treatment of distal radius fractures. It also outlines potential improvements that could be made. A study of patients undergoing treatment for distal radius fracture was undertaken. We analysed the risks and complications recorded on the consent form. The common recorded risks were infection (95.6%), vascular injuries (77.8%), nerve injuries (66.7%) and stiffness (42.2%); 31.1% of the consent forms had abbreviations. Junior doctors who consented the patients performed 6.7% of the procedures. The poor documentation of risks or complications indicates that patients are not given appropriate information to ensure that the consent is valid. Proper documentation and refining of consent forms is mandatory to ensure that all major risks are understood by patients. This could go a long way in preventing litigation.


Assuntos
Termos de Consentimento/normas , Consentimento Livre e Esclarecido/normas , Ortopedia/normas , Fraturas do Rádio/cirurgia , Medicina de Emergência/legislação & jurisprudência , Medicina de Emergência/métodos , Feminino , Humanos , Jurisprudência , Masculino , Pessoa de Meia-Idade , Ortopedia/legislação & jurisprudência , Complicações Pós-Operatórias , Registros , Estudos Retrospectivos , Fatores de Risco
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...